Buy 102-205-101 Aircraft Part of Wood Electric Operations Potter And - Request A Quote Now
An NSN is a 13-digit numeric code that serves to identify 'standardized material items of supply' as they have been recognized by all NATO countries and the United States Department of Defense. Aviation Gamut, owned and operated by ASAP Semiconductor, is an all-inclusive purchasing platform for hard-to-find and in-demand 102-205-101 parts and components pertaining to the civil aviation, defense, aerospace, industrial, and electronic markets. As such, we have an inventory of more than two billion new and obsolete parts, among which is an unparalleled selection of NSN parts and much more. This includes items such as 102-205-101 from manufacturer Wood Electric Operations Potter And and many more, all of which are available with short lead times and competitive prices. For NSN parts, Aviation Gamut is the ultimate source.
Specifications
Request a Quote
Get pricing for 102-205-101
NSN Information for Part Number 102-205-101 with NSN 5925-00-877-6757, 5925008776757
Characteristics Data of NSN 5925-00-877-6757, 5925008776757
| MRC | Criteria | Characteristic |
|---|---|---|
| CQXF | Inclosure Protection Type For Which Designed | VIBRATIONPROOF |
| AAQL | Body Style | SINGLE POLE TYPE |
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.812 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC AND |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| ABXD | Bushing Length | 0.156 INCHES NOMINAL |
| FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC AND |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 32.0 DC SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3000.0 DC SINGLE LOCATION |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3000.0 AC AND |
| CRCF | Trip Release Ambient Temp Rating | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
| CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
| AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
| AKPX | Pole Quantity | 1 |
| CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| ADAT | Body Width | 0.750 INCHES NOMINAL |
| CPRQ | Reset Method | MANUAL |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 SINGLE LOCATION |
| CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
| CPRW | Actuator Function | TRIP-RESET |
| ADTV | Case Material | PLASTIC |
| CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| CPRX | Actuator Position Designation | AT POLE ONE |
| CQJX | Nominal Thread Size | 0.138 INCHES |
| AJWX | Mounting Surface To Terminal End Distance | 2.000 INCHES NOMINAL |
| ADAQ | Body Length | 2.189 INCHES NOMINAL |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.188 INCHES NOMINAL |
| THSD | Thread Series Designator | UNC |
| TTQY | Terminal Type And Quantity | 2 SCREW |
| MRC | Decoded Requirement | Clear Text Reply |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
| CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 18.000 MINIMUM AT 200 PCT AND |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CMLP | Thread Quantity Per Inch | 32 |
| CQXF | Inclosure Protection Type For Which Designed | SALT SPRAY PROOF AND |