An NSN is a 13-digit numeric code that serves to identify 'standardized material items of supply' as they have been recognized by all NATO countries and the United States Department of Defense. Aviation Gamut, owned and operated by ASAP Semiconductor, is an all-inclusive purchasing platform for hard-to-find and in-demand 014240-0007 parts and components pertaining to the civil aviation, defense, aerospace, industrial, and electronic markets. As such, we have an inventory of more than two billion new and obsolete parts, among which is an unparalleled selection of NSN parts and much more. This includes items such as Circuitbreaker 014240-0007 from manufacturer Thales Defense And Security Inc and many more, all of which are available with short lead times and competitive prices. For NSN parts, Aviation Gamut is the ultimate source.
Specifications
Description
Request a Quote
Get pricing for 014240-0007
NSN Information for Part Number 014240-0007 with NSN 5925-01-045-2930, 5925010452930
Characteristics Data of NSN 5925-01-045-2930, 5925010452930
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
| ABHP | OVERALL LENGTH | 2.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 1.770 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 0.920 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 TERMINAL |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 1.0 AMPERES AC AND 1.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 120.0 AC AND 32.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC AND 1000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT,MALE |