Mfg Part Number: PEI6609 | NSN : 5950-00-946-3305 | NIIN : 009463305 |
CAGE Code : 13483 | Manufacturer: Precision Electronics Inc | Item Name : Transformer Power |
FSC : 5950 Coils and Transformers |
Aviation Gamut, owned and operated by ASAP Semiconductor, is an all-inclusive purchasing platform for hard-to-find and in-demand parts PEI6609 and components pertaining to the civil aviation, defense, aerospace, industrial, and electronic markets. An NSN is a 13-digit numeric code that serves to identify 'standardized material items of supply' as they have been recognized by all NATO countries and the United States Department of Defense. As such, we have an inventory of more than two billion new and obsolete parts, among which is an unparalleled selection of NSN parts and much more. This includes items such as Transformer Power PEI6609 from manufacturer Precision Electronics Inc and many more, all of which are available with short lead times and competitive prices. For NSN parts, Aviation Gamut is the ultimate source.
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for PEI6609. This means you can quickly sort through National Stock Numbers such as 5950009463305 and find parts from quality manufacturers like Precision Electronics Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-946-3305 Item Description: Transformer Power | 5950 | 009463305 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Pei6609 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.190 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.210 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.510 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.530 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO TWO PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA |
ADAQ | BODY LENGTH | 2.860 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.250 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.300 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 170.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.02 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 11.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 825.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 200.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 38.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 133.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.638 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 22.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 26.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 9.3 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 16.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 19.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 54.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY AND 70.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 37.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 94.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 114.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 3.47 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 58.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS WITH FIRST,SECOND,FOURTH,AND FIFTH WINDINGS CENTER TAPPED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 23 TAB, SOLDER LUG |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote